Internationaal Verdrag van Torremolinos voor de beveiliging van vissersvaartuigen, 1977
(1) Every steam boiler and every unfired steam generator shall be provided with not less than two safety valves of adequate capacity. Provided that the Administration may, having regard to the output or any other features of any steam boiler or unfired steam generator, permit only one safety valve to be fitted if satisfied that adequate protection against overpressure is thereby provided.
(2) Every oil fired steam boiler which is intended to operate without manual supervision shall have safety arrangements which shut off the fuel supply and give an alarm in the case of low water level, air supply failure or flame failure.
(3) The Administration shall give special consideration to steam boiler installations to ensure that feed systems, monitoring devices, and safety provisions are adequate in all respects to ensure the safety of boilers, steam pressure vessels and steam piping arrangements.