Artikel 55
Internationaal Verdrag van Torremolinos voor de beveiliging van vissersvaartuigen, 1977
(1) A self-contained emergency source of electrical power located, to the satisfaction of the Administration, outside the machinery spaces shall be provided and so arranged as to ensure its functioning in the event of fire or other causes of failure of the main electrical installations.
(2) The emergency source of electrical power shall be capable, having regard to starting current and the transitory nature of certain loads, of serving simultaneously for a period of at least three hours: (a) internal communication equipment, fire detecting systems and signals which may be required in an emergency;
(b) the navigation lights if solely electrical and the emergency lights: (i) of launching stations and overside of the vessel;
(ii) in all alleyways, stairways and exits;
(iii) in spaces containing machinery or the emergency source of power;
(iv) in control stations; and
(v) in fish handling and fish processing spaces; and
(i) of launching stations and overside of the vessel;
(ii) in all alleyways, stairways and exits;
(iii) in spaces containing machinery or the emergency source of power;
(iv) in control stations; and
(v) in fish handling and fish processing spaces; and
(c) the operation of the emergency fire pump, if any.
(a) internal communication equipment, fire detecting systems and signals which may be required in an emergency;
(b) the navigation lights if solely electrical and the emergency lights: (i) of launching stations and overside of the vessel;
(ii) in all alleyways, stairways and exits;
(iii) in spaces containing machinery or the emergency source of power;
(iv) in control stations; and
(v) in fish handling and fish processing spaces; and
(i) of launching stations and overside of the vessel;
(ii) in all alleyways, stairways and exits;
(iii) in spaces containing machinery or the emergency source of power;
(iv) in control stations; and
(v) in fish handling and fish processing spaces; and
(c) the operation of the emergency fire pump, if any.
(3) The emergency source of electrical power may be either a generator or an accumulator battery.
(4) (a) Where the emergency source of electrical power is a generator, it shall be provided both with an independent fuel supply and with efficient starting arrangements to the satisfaction of the Administration. Unless a second independent means of starting the emergency generator is provided the single source of stored energy shall be protected to preclude its complete depletion by the automatic starting system.
(b) Where the emergency source of electrical power is an accumulator battery it shall be capable of carrying the emergency load without recharging whilst maintaining the voltage of the battery throughout the discharge period within plus or minus 12 per cent of its nominal voltage. In the event of failure of the main power supply this accumulator battery shall be automatically connected to the emergency switchboard and shall immediately supply at least those services specified in paragraph (2)(a) and (b). The emergency switchboard shall be provided with an auxiliary switch allowing the battery to be connected manually, in case of failure of the automatic connexion system.
(a) Where the emergency source of electrical power is a generator, it shall be provided both with an independent fuel supply and with efficient starting arrangements to the satisfaction of the Administration. Unless a second independent means of starting the emergency generator is provided the single source of stored energy shall be protected to preclude its complete depletion by the automatic starting system.
(b) Where the emergency source of electrical power is an accumulator battery it shall be capable of carrying the emergency load without recharging whilst maintaining the voltage of the battery throughout the discharge period within plus or minus 12 per cent of its nominal voltage. In the event of failure of the main power supply this accumulator battery shall be automatically connected to the emergency switchboard and shall immediately supply at least those services specified in paragraph (2)(a) and (b). The emergency switchboard shall be provided with an auxiliary switch allowing the battery to be connected manually, in case of failure of the automatic connexion system.
(5) The emergency switchboard shall be installed as near as is practicable to the emergency source of power and shall be located in accordance with paragraph (1). Where the emergency source of power is a generator, the emergency switchboard shall be located in the same place unless the operation of the emergency switchboard would thereby be impaired.
(6) An accumulator battery fitted in accordance with this Regulation, other than batteries fitted for the radio transmitter and receiver in vessels of less than 45 metres in length, shall be installed in a well ventilated space which shall not be the space containing the emergency switchboard. An indicator shall be mounted in a suitable place on the main switchboard or in the machinery control room to indicate when the battery constituting the emergency source of power is being discharged. The emergency switchboard is to be supplied in normal operation from the main switchboard by an inter-connector feeder which is to be protected at the main switchboard against overload and short circuit. The arrangement at the emergency switchboard shall be such that the inter-connector feeder is disconnected automatically at the emergency switchboard upon failure of the main power supply, and for vessels of 45 metres in length and over shall provide for automatic connexion of the emergency supply in the event of such failure. When the system is arranged for feedback operation, the inter-connector feeder shall also be protected at the emergency switchboard at least against short circuit.
(7) The emergency generator and its prime mover and any accumulator battery shall be so arranged as to ensure that they will function at full rated power when the vessel is upright and when rolling up to an angle of 22½ degrees either way and simultaneously pitching 10 degrees by bow or stern, or is in any combination of angles within those limits.
(8) The emergency source of electrical power and automatic starting equipment shall be so constructed and arranged as to enable adequate testing to be carried out by the crew while the vessel is in operating condition.
(2) The emergency source of electrical power shall be capable, having regard to starting current and the transitory nature of certain loads, of serving simultaneously for a period of at least three hours: (a) internal communication equipment, fire detecting systems and signals which may be required in an emergency;
(b) the navigation lights if solely electrical and the emergency lights: (i) of launching stations and overside of the vessel;
(ii) in all alleyways, stairways and exits;
(iii) in spaces containing machinery or the emergency source of power;
(iv) in control stations; and
(v) in fish handling and fish processing spaces; and
(i) of launching stations and overside of the vessel;
(ii) in all alleyways, stairways and exits;
(iii) in spaces containing machinery or the emergency source of power;
(iv) in control stations; and
(v) in fish handling and fish processing spaces; and
(c) the operation of the emergency fire pump, if any.
(a) internal communication equipment, fire detecting systems and signals which may be required in an emergency;
(b) the navigation lights if solely electrical and the emergency lights: (i) of launching stations and overside of the vessel;
(ii) in all alleyways, stairways and exits;
(iii) in spaces containing machinery or the emergency source of power;
(iv) in control stations; and
(v) in fish handling and fish processing spaces; and
(i) of launching stations and overside of the vessel;
(ii) in all alleyways, stairways and exits;
(iii) in spaces containing machinery or the emergency source of power;
(iv) in control stations; and
(v) in fish handling and fish processing spaces; and
(c) the operation of the emergency fire pump, if any.
(3) The emergency source of electrical power may be either a generator or an accumulator battery.
(4) (a) Where the emergency source of electrical power is a generator, it shall be provided both with an independent fuel supply and with efficient starting arrangements to the satisfaction of the Administration. Unless a second independent means of starting the emergency generator is provided the single source of stored energy shall be protected to preclude its complete depletion by the automatic starting system.
(b) Where the emergency source of electrical power is an accumulator battery it shall be capable of carrying the emergency load without recharging whilst maintaining the voltage of the battery throughout the discharge period within plus or minus 12 per cent of its nominal voltage. In the event of failure of the main power supply this accumulator battery shall be automatically connected to the emergency switchboard and shall immediately supply at least those services specified in paragraph (2)(a) and (b). The emergency switchboard shall be provided with an auxiliary switch allowing the battery to be connected manually, in case of failure of the automatic connexion system.
(a) Where the emergency source of electrical power is a generator, it shall be provided both with an independent fuel supply and with efficient starting arrangements to the satisfaction of the Administration. Unless a second independent means of starting the emergency generator is provided the single source of stored energy shall be protected to preclude its complete depletion by the automatic starting system.
(b) Where the emergency source of electrical power is an accumulator battery it shall be capable of carrying the emergency load without recharging whilst maintaining the voltage of the battery throughout the discharge period within plus or minus 12 per cent of its nominal voltage. In the event of failure of the main power supply this accumulator battery shall be automatically connected to the emergency switchboard and shall immediately supply at least those services specified in paragraph (2)(a) and (b). The emergency switchboard shall be provided with an auxiliary switch allowing the battery to be connected manually, in case of failure of the automatic connexion system.
(5) The emergency switchboard shall be installed as near as is practicable to the emergency source of power and shall be located in accordance with paragraph (1). Where the emergency source of power is a generator, the emergency switchboard shall be located in the same place unless the operation of the emergency switchboard would thereby be impaired.
(6) An accumulator battery fitted in accordance with this Regulation, other than batteries fitted for the radio transmitter and receiver in vessels of less than 45 metres in length, shall be installed in a well ventilated space which shall not be the space containing the emergency switchboard. An indicator shall be mounted in a suitable place on the main switchboard or in the machinery control room to indicate when the battery constituting the emergency source of power is being discharged. The emergency switchboard is to be supplied in normal operation from the main switchboard by an inter-connector feeder which is to be protected at the main switchboard against overload and short circuit. The arrangement at the emergency switchboard shall be such that the inter-connector feeder is disconnected automatically at the emergency switchboard upon failure of the main power supply, and for vessels of 45 metres in length and over shall provide for automatic connexion of the emergency supply in the event of such failure. When the system is arranged for feedback operation, the inter-connector feeder shall also be protected at the emergency switchboard at least against short circuit.
(7) The emergency generator and its prime mover and any accumulator battery shall be so arranged as to ensure that they will function at full rated power when the vessel is upright and when rolling up to an angle of 22½ degrees either way and simultaneously pitching 10 degrees by bow or stern, or is in any combination of angles within those limits.
(8) The emergency source of electrical power and automatic starting equipment shall be so constructed and arranged as to enable adequate testing to be carried out by the crew while the vessel is in operating condition.