1. The location, means of access, structure and arrangement of crew accommodation in relation to other spaces shall be such as to ensure adequate security, protection against weather and sea and insulation from heat or cold, undue noise or effluvia from other spaces.
2. Emergency escapes shall be provided from all crew accommodation spaces as necessary.
3. Every effort shall be made to exclude direct openings into sleeping rooms from fish holds and fish meal rooms, from spaces for machinery, from galleys, lamp and paint rooms or from engine, deck and other bulk store rooms, drying rooms, communal wash places or water closets. That part of the bulkhead separating such places from sleeping rooms and external bulkheads shall be efficiently constructed of steel or other approved substance and shall be watertight and gastight.
4. External bulkheads of sleeping rooms and mess rooms shall be adequately insulated. All machinery casings and all boundary bulkheads of galleys and other spaces in which heat is produced shall be adequately insulated when there is a possibility of resulting heat effects in adjoining accommodation or passageways. Care shall also be taken to provide protection from heat effects of steam and/or hot-water service pipes.
5. Internal bulkheads shall be of approved material which is not likely to harbour vermin.
6. Sleeping rooms, mess rooms, recreation rooms and passageways in the crew accommodation space shall be adequately insulated to prevent condensation or over-heating.
7. Main steam and exhaust pipes for winches and similar gear shall, whenever technically possible, not pass through crew accommodation or through passageways leading to crew accommodation; where they do pass through such accommodation or passageways they shall be adequately insulated and encased.
8. Inside panelling or sheeting shall be of material with a surface easily kept clean. Tongued and grooved boarding or any other form of construction likely to harbour vermin shall not be used.
9. The competent authority shall decide to what extent fire prevention or fire retarding measures shall be required to be taken in the construction of the accommodation.
10. The wall surface and deckheads in sleeping rooms and mess rooms shall be easily kept clean and, if painted, shall be light in colour; lime wash must not be used.
11. The wall surfaces shall be renewed or restored as necessary.
12. The decks in all crew accommodation shall be of approved material and construction and shall provide a surface impervious to damp and easily kept clean.
13. Overhead exposed decks over crew accommodation shall be sheathed with wood or equivalent insulation.
14. Where the floorings are of composition the joinings with sides shall be rounded to avoid crevices.
15. Sufficient drainage shall be provided.
16. All practicable measures shall be taken to protect crew accommodation against the admission of flies and other insects.
2. Emergency escapes shall be provided from all crew accommodation spaces as necessary.
3. Every effort shall be made to exclude direct openings into sleeping rooms from fish holds and fish meal rooms, from spaces for machinery, from galleys, lamp and paint rooms or from engine, deck and other bulk store rooms, drying rooms, communal wash places or water closets. That part of the bulkhead separating such places from sleeping rooms and external bulkheads shall be efficiently constructed of steel or other approved substance and shall be watertight and gastight.
4. External bulkheads of sleeping rooms and mess rooms shall be adequately insulated. All machinery casings and all boundary bulkheads of galleys and other spaces in which heat is produced shall be adequately insulated when there is a possibility of resulting heat effects in adjoining accommodation or passageways. Care shall also be taken to provide protection from heat effects of steam and/or hot-water service pipes.
5. Internal bulkheads shall be of approved material which is not likely to harbour vermin.
6. Sleeping rooms, mess rooms, recreation rooms and passageways in the crew accommodation space shall be adequately insulated to prevent condensation or over-heating.
7. Main steam and exhaust pipes for winches and similar gear shall, whenever technically possible, not pass through crew accommodation or through passageways leading to crew accommodation; where they do pass through such accommodation or passageways they shall be adequately insulated and encased.
8. Inside panelling or sheeting shall be of material with a surface easily kept clean. Tongued and grooved boarding or any other form of construction likely to harbour vermin shall not be used.
9. The competent authority shall decide to what extent fire prevention or fire retarding measures shall be required to be taken in the construction of the accommodation.
10. The wall surface and deckheads in sleeping rooms and mess rooms shall be easily kept clean and, if painted, shall be light in colour; lime wash must not be used.
11. The wall surfaces shall be renewed or restored as necessary.
12. The decks in all crew accommodation shall be of approved material and construction and shall provide a surface impervious to damp and easily kept clean.
13. Overhead exposed decks over crew accommodation shall be sheathed with wood or equivalent insulation.
14. Where the floorings are of composition the joinings with sides shall be rounded to avoid crevices.
15. Sufficient drainage shall be provided.
16. All practicable measures shall be taken to protect crew accommodation against the admission of flies and other insects.
- Citeren als